This page gathers the technical details, certifications and safety information for the OlyLife P90 in one place. It goes with our Tera-P90 product page.
Unless we say otherwise, every figure and safety rule here comes from the official Tera-P90 instruction manual (updated 7 October 2024).
What’s in the box
- THz Tera-P90 main unit (foot platform)
- Remote control
- Power cord
- Instruction manual with warranty card
Specifications
| Model | P90 |
| Operating voltage | 220 to 240 V |
| Output power | 270 W |
| Size | 379 x 123 x 371 mm |
| Session length | 30 minutes, counting down on the display |
| Intensity | Adjustable with the + and – buttons on the unit or the remote. Each session starts at level 01. |
| Heater switch | A separate switch warms the plates before you start, useful on cold days |
| Controls | Operation panel with standby, working, time and strength indicators, plus a remote control |
| Automatic standby | If a foot leaves the plates for more than 10 seconds, the unit stops and returns to standby |
Independent terahertz testing
In 2023, Guangzhou Zhongsen Testing Technology measured the radiation output of the Tera-P90 (report ZSJC2023042607). The strongest band was 30 to 1,000 micrometres, which sits in the terahertz range. About a quarter of the total output fell in the terahertz band. You can read the full test report (PDF).
For what terahertz waves are and what the research says, see our terahertz article.
Using the Tera-P90
- Place the unit on a flat floor. Don’t use it on a slope or uneven surface.
- Switch on the power. The panel lights up and the standby light shows red.
- If the plates feel cold, press the heater switch to warm them. Turn it off again once they feel warm.
- Sit down and place your bare, dry feet on the plates, one foot on each. The working light turns green and the session starts at 30 minutes, strength 01.
- Raise the strength gradually with the + button until it feels comfortable. Lower it if the soles of your feet feel hot.
- The timer counts down in one-minute steps. At 01 the unit returns to standby.
- Turn the unit off and unplug it after each session.
Session limits
- The manual doesn’t recommend sessions longer than 30 minutes.
- After 30 minutes of continuous use, let the unit rest for 20 minutes.
- Don’t wear socks, and don’t put any cover over the plates.
Certifications and registrations
These are the certificates OlyLife has supplied for the Tera-P90.
- CB test certificate (IEC electrical safety), issued through Intertek
- CE verifications of conformity for low-voltage safety (LVD) and electromagnetic compatibility (EMC), issued through Intertek
- South Korean KC conformity registration
- US FDA registration. OlyLife’s devices are FDA registered, not FDA approved. Registration lists a device with the FDA. It isn’t an approval of any health claim. Our article on FDA registered vs. FDA approved explains the difference.




Safety and precautions
The rules below come from the Tera-P90 manual. Please read them before your first session.
Who shouldn’t use the Tera-P90
- people with heart disease
- pregnant women and infants
- people with lung conditions
- people with impaired consciousness
- anyone with a body temperature above 37°C
- people using life-support equipment, such as heart-lung machines
- people with a bleeding tendency, such as uterine fibroids, or during menstruation
- people with reduced sensitivity to heat in the legs or feet, such as from a disc herniation pressing on nerves, or diabetic feet
- people with implants such as cardiac pacemakers, or any other metal implant
Don’t use it for children or anyone who can’t tell you how they feel. If you’ve recently had a salon or clinic treatment that left your skin very red or swollen, check with a doctor first.
While you use it
- Make sure your hands and feet are dry. Remove any metal objects you’re wearing.
- Keep your whole sole on the plate. Don’t let your legs touch each other.
- Don’t touch your feet, ankles, knees or the plates with your hands during a session. Don’t touch other people either.
- Keep metal objects away from the plates.
- Don’t use it at the same time as any other electrotherapy or electromagnetic device.
- Don’t use it in a bathroom, while showering, or anywhere very hot or humid.
- Don’t use the unit as a heater, and don’t cover it with anything.
- If you feel anything unusual, stop straight away. In an emergency, such as a power failure or malfunction, switch it off immediately.
- If you notice smoke or a strange smell, unplug it and contact us.
Care and maintenance
- Turn it off and unplug it after every use.
- Clean the plates and control panel with a damp cloth. Never clean them with running water.
- Avoid leaving it running with no one on it.
The Tera-P90 is a wellness device. It isn’t intended to diagnose, treat, cure or prevent any disease. If you have a health condition, talk to your doctor before you start.
Warranty and support
The Tera-P90 comes with OlyLife’s 24-month warranty from the date of purchase, with no repair fees during that time. Keep your warranty card and sales invoice, as you’ll need both for any claim. Damage from misuse or modification isn’t covered, but OlyLife still offers paid repairs. See our FAQ for how returns and repairs work, or use the form below with any questions.
Sources
- OlyLife THz Tera-P90 instruction manual, model P90 (updated 7 October 2024)
- OlyLife THz Tera-P90 test report ZSJC2023042607, Guangzhou Zhongsen Testing Technology Co., Ltd (2023)
- Certificates as supplied by OlyLife, shown above
Interested in this product?
Want to hear more about it? Ready to own it? Let us know your details below. We aim to reply within one business day.